搜索结果: 1-7 共查到“生物医学测量学 device might”相关记录7条 . 查询时间(0.093 秒)
Development of a Micro-fluid Device for Blood Tests
μTAS UV laser lamination resin-films blood cells
2009/6/9
Many studies have been carried out in order to understand the real effects of space environment on the human body. Our aim is to create a very small, energy-saving vital signs monitoring device capabl...
Development and Evaluation of a Full-size Experimental Device to Determine Sliding Door Usability by Elderly People
Elderly people sensory evaluation sliding door applied force universal design
2009/6/9
A full-size experimental device was developed where the opening and closing forces were controlled independently from the weight of a door. In the experiment, three door weights, 20, 40 and 60 kgf, an...
Quantitative Assessment System for Gait of the Elderly Using a Portable Acceleration Monitor Device
elderly people gait quantitative assessment acceleration
2009/6/9
In this study, a handy gait assessment system with a tri-axial accelerometer has been developed and its application for quantitatively assessing the gait of elderly people was examined. This assessmen...
Testing limits to airflow perturbation device (APD) measurements
Testing airflow perturbation device (APD) measurements
2010/2/25
The APD can be adapted for use in ventilated, unconscious, and uncooperative patients with use of a ventilator tube and an oronasal mask without significantly affecting measurements. Adding a resistan...
Continuous cytometric bead processing within a microfluidic device for bead based sensing platforms
Continuous cytometric bead processing microfluidic device bead based sensing platforms
2009/12/24
A microfluidic device for continuous biosensing based on analyte binding with cytometric beads is introduced. The operating principle of the continuous biosensing is based on a novel concept
named th...
A microfluidic device for continuous,real time blood plasma separation
microfluidic device continuous real time blood plasma separation
2009/12/24
A microfluidic device for continuous, real time blood plasma separation is introduced. The
principle of the blood plasma separation from blood cells is supported by the Zweifach–Fung
effect and was ...
Validity and reproducibility of arterial pulse wave velocity measurement using new device with oscillometric technique: A pilot study
arterial pulse wave velocity measurement oscillometric technique
2010/2/26
Pulse wave velocity and arterial stiffness index were recorded in 24 control and 20 coronary artery disease patients. All the velocities were significantly high in coronary artery disease patients. Th...